nEASY INSTALLATION
•Easy Wiring Knockout
•Wiring Guide
·Spare Terminal [MX-40QZ/50QZ/40PT Only]
•Tamper Terminal [MX-40QZ/50QZ/40PT Only]
·D.L. Terminal [MX-40QZ(BE)/50QZ(BE) Only]
•Wide Wiring Space
nFEATURES
•40ft.×40ft.(12m×12m)Wide Angle [MX-40 Series]
•50ft.×50ft.(15m×15m)Wide Angle [MX-50 Series]
•QUAD Zone Logic
•Patented Multi-focus Lens
•Improved Sealed Optics
•Temperature Compensation Logic
•Pet Immunity [MX-40PI/PT Only]
(See Section 5 for Pet Immunity)
nFUNCTION
•Selectable Pulse Count(2 or 4)
•LED ON/OFF
•Tamper Switch [MX-40QZ/50QZ/40PT Only]
•Microwave Range Selector(LONG or SHORT)
nOPTION
•FA-3 Wall & Ceiling Mount Bracket
(Horizontally ±45°& Vertically 0°to-15°)
2. DESCRIPTION,OPERATION and DIMENSIONS
TAMPERSP
DL
ALARM
Corner mount
knockout
Wiring knockout
P.C.B. unit
Tamper switch
Terminals
2.44(62)
Cover
LED Indicator
Lens
Base
Wiring guide
Mounting knockout
(Pitch=3.29"/83.5mm)
(Pitch=3.58"/91.0mm)
Fastening screw
inch(mm)
3. DETECTION AREA
WIDE ANGLE
n
TOP VIEW
n
SIDE VIEW
1. INSTALLATION HINTS
Use the pin switch
for Pulse Count
Selection ( 2 or 4 ).
Use the pin switch
for LED ON/OFF .
n LED ON/OFF
n
PULSE COUNT
With PET IMMUNITY&TAMPER
MX-40PT
With PET IMMUNITY
MX-40PIMX-40QZ MX-50QZ
PASSIVE INFRARED and MICROWAVE
COMBINATION DETECTOR
P.C.B. hook
MX-40 AREA
MX-50 AREA
30
35
25
50 ft
35
30
0
10
9 12
8 ft
15m
50 ft
25
9
4
S
2
0
2
5
10
2015
20
6
2.2m
0
1510
5
0
3
3
4
S
15m
40 45
12
40
45
5
15
20
S
5
10
15
20
25 ft
8m
25 ft
8m
1.5m
3.0m
2.4m
5 f
t
7.5 ft
10 ft
No.59-0967-0 0009-25
N219
4
2
OFF
ON
n
D.L. TERMINAL D.L. TERMINAL
D.L. TERMINAL D.L. TERMINAL
D.L. TERMINAL
(MX-40QZ(BE),MX-50QZ(BE) Only)
LED can be enabled or disabled remotely from control panel by D.L. terminal.
Place jumper pin switch in OFF position.
n
MICR
OO
OO
OWAVE
RANGE
LONG
SHORT
n
EASY WIRING KNOCKOUTS
Press firmly with a screwdriver to
open.Enlarge the hole according
to size of wire.
LED Enabled Connect D.L. terminal to common ground(with detector).
LED Disabled No ground to D.L. terminal (open circuit).
Avoid
Curtain,Screen,etc.
blocking detection area.
Avoid vapor or high
humidity that can cause
condensation.
Avoid direct sunlight.
Do not install outdoors.
Do not aim towards outside areas where there is
frequent movement.
Do not mount in unstable location
where vibration or shock may
affect the detector.
Do not install unit near
fluorescent lights.
Avoid mounting detector where
movement of Fans or Air
Conditioning can be detected.
Do not aim detection area
towards equipment which
continually moves in the
detection area (i.e.curtain,
blinds).
P.I.R. Sensor
Do not touchDo not touch
Do not touchDo not touch
Do not touch!
Do not touchDo not touch
Do not touchDo not touch
Do not touch!
Microwave Sensor
Select RANGE SELECTOR
according to the room size.
(SHORT or LONG)
MX-40 Series
Select RANGE SELECTOR
"SHORT" when it's used with 24ft
(7 m)square and Smaller room.
MX-50 Series
Select RANGE SELECTOR
"SHORT" when it's used with 34ft
(10m)square and Smaller room.

Other manuals for Optex MX-40QZ

Question and Answer IconNeed help?

Do you have a question about the Optex MX-40QZ and is the answer not in the manual?

Optex MX-40QZ Specifications

General IconGeneral
Operating Temperature-20°C to +50°C
TypePassive Infrared Sensor
Detection MethodPassive Infrared
Tamper SwitchNormally Closed (NC)
Detection Range12m x 12m (40ft x 40ft)
Alarm OutputNormally Closed (NC) relay contact

Summary

Installation Hints

Avoid Direct Sunlight

Warning against exposing the detector to direct sunlight during installation.

Avoid Airflow Interference

Do not mount where fans or AC movement can be detected or in humid areas.

Clear Detection Path

Ensure no curtains, screens, or moving equipment obstruct the detection area.

Stable Mounting

Avoid unstable locations where vibration or shock might affect detector performance.

Description, Operation, and Dimensions

LED ON/OFF Control

Explanation of the pin switch function for controlling the LED indicator.

Pulse Count Selection

Explanation of the pin switch for selecting the Pulse Count (2 or 4).

Microwave Range Setting

Guidance on selecting the Microwave Range (SHORT or LONG) based on room size.

D.L. Terminal Function

Details on using the D.L. terminal for remote LED control via a jumper pin switch.

Detection Area

Wide Angle Top View

Top view illustration of the detector's wide-angle detection pattern and range.

Side View Detection

Side view illustration of the detector's detection pattern and range for different mounting heights.

Installation and Wiring

Pet Immunity Guidelines

Specific instructions for installing detectors to ensure effective pet immunity.

Wiring Specifications

Guidelines on wiring, including power input, alarm output, and wire length limits.

Troubleshooting and Maintenance

Problem Resolution

Guidance on diagnosing and resolving common issues like LED not lighting or false alarms.

Specifications and Compliance

Model Specifications

Detailed technical specifications for MX-40QZ/PI/PT and MX-50QZ models.

Regulatory Compliance

Information on R&TTE Directive conformity and FCC rules for the equipment.

Related product manuals