37
IEGB
Trouble shooting
Problem Possible cause Remedy
Abnormal noises,
clatter or vibra-
tions
Foreign body on cylinder
(
16/17)
Remove foreign body
Damaged sprung tines
(
16) or cylinder knives
(
17)
Exchange cylinder
Cylinder (
16/17) incor-
rectly mounted
Install cylinder correctly (see “Ex-
changing the cylinder”)
Toothed-belt slip
Switch device off and pull power
plug. Remove the soil and grass resi-
dues available.
Implement does
not start
No power
Check power socket, cable, line; re-
pair only by qualifi ed electrician
Starting lever (
2) defec-
tive
Repair by After-Sales Service
Carbon brushes worn out
Motor defective
Motor fails
Blocked by foreign body Remove foreign body
Grass is too long
Mow beforehand; see chapter “Op-
eration”
Clogged discharge Clean discharge
Overload protection tripped
Allow implement to cool down for
about 1 minute
Work result not
satisfactory
Sprung tines of aerator cylin-
der (
16) worn out
Exchange cylinder (16/17)
Knives of verticutor cylinder
(
17) blunt or damaged
Toothed belt defective Repair by After-Sales Service
Transport Position or incor-
rect Working Position se-
lected
see chapter “Setting the Working
Positions”
Grass is too long
Mow beforehand; see chapter “Op-
eration”