Pump does not work
• Check mains current (do not use a pin gauge)
• Fuse faulty = may be too weak (please refer to
Electrical Connection)
• Mains supply cable damaged = repair to be
carried out by manufacturer only
Pump runs but does not pump
• Empty the pressure pipe or hose to allow the
non-return valve to open and the air to escape
from the pump housing, it may be necessary
to carry out a ventilation drilling
Impeller blocked
• Solids and brous matter have become lod-
ged in the pump housing = clean
Decreased pumping performance
• Foot strainer obstructed = clean
• Pressure pipe obstructed = clean
• Rotor worn out = repair to be carried out by
the manufacturer
• Wrong direction of rotation (for a three-pha-
se current) = ask a qualied electrician to
change 2 phases of the supply line
0197
JUNG PUMPEN GmbH - Industriestr. 4-6
33803 Steinhagen, Germany
13
401.14.1810
EN 12050-2:2001
Lifting plant for faecal-free wastewater DN 32
U3 K (JP00205/2)
U3 K spez. (JP09562/2)
U3 KS (JP00206/2)
U3 K spez. (JP44255)
U3 KS (JP09808/2)
U3 KS spez. (JP09563/2)
U3 KS spez. (JP45195)
U5 K (JP09386/0)
U5 KS (JP09387/0)
U5 KS (JP09417/0)
U6 K E (JP00226/2)
U6 K D (JP00228/3)
U6 K ES (JP00227/2)
U6 K ES (JP09260/2)
U6 K DS (JP00229/3)
U6 K DS (JP09261/3)
Collecting and automatically lifting faecal-free
waste water above the backow level in buildings
and sites
REACTION TO FIRE NPD
WATERTIGHTNESS Pass
EFFECTIVENESS (LIFTING EFFECT
- Pumping of solids Pass
- Pipe connections Pass
- Ventilation NPD
- Minimum ow velocity Pass
-
Minimum free passage of the plant
Pass
- Minimum useful volume NPD
MECHANICAL RESISTANCE
- Load bearing capacity and structural
stability of collection tank for use
NPD
- Structural stability of collection tank
for use inside buildings
NPD
NOISE LEVEL 70 dB(A)
DURABILITY
- of structural stability NPD
- of lifting effectiveness Pass
- of mechanical resistance NPD
DANGEROUS SUBSTANCES
NPD