EasyManuals Logo
Home>Perlick>Refrigerator>SIGNATURE 15 Series

Perlick SIGNATURE 15 Series Service Manual

Perlick SIGNATURE 15 Series
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
COMPRESSOR
MODEL HP
MOTOR
TYPE
START
WINDING
RESISTANCE
Ω AT 77°F
(+/-8%)
RUN
WINDING
RESISTANCE
Ω AT 77°F
(+/-8%)
LOCKED
ROTOR
AMPERAGE
(LRA)
STARTING
DEVICE
MOTOR
PROTECTION
CAPACITOR
(Run/Start)
(uF/VAC Minimum)
EM30HHR 1/10 RSIR 20.9 5.5 14.5
Current
Relay
4TM575MFBYY-
53
N/A
EM65HHC 1/6+ RSCR 3.7 3.2 15.0 PTC
4TM427NFBYY-
53
Run (20/170)
EM20HSC 1/10 RSCR 13.2 9.3 5.2 TSD2-115V
4TM189KFBYY-
53
Run (5/175)
EM3D50HLT 1/5 RSCR 5.9 5.4 8.0
TSD2-
115V0.6
4TM302KFBYY-
53
Run (15/200 or
12/200)
VEGY3H 1/10 BPM 16.1 16.1 2.1 Inverter Inverter N/A
VEGY7H 1/4 BPM 6.4 6.4 3.3 Inverter Inverter N/A
Return to Table of Contents
Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
Compressors
Table 7-2. Compressor Data
Refrigeration System Repair Instructions Page 7-8

Table of Contents

Other manuals for Perlick SIGNATURE 15 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Perlick SIGNATURE 15 Series and is the answer not in the manual?

Perlick SIGNATURE 15 Series Specifications

General IconGeneral
BrandPerlick
ModelSIGNATURE 15 Series
CategoryRefrigerator
LanguageEnglish

Related product manuals