Mark reset of single suppressed signals: To reset the MARK function for single signals, press
the button MARK for 3 seconds.
Mark reset of all suppressed signals: To reset the MARK function switch your PIEPS DSP
PRO/DSP SPORT into SEND-mode and then back to SEARCH-mode. With the PIEPS DSP PRO
you also have the possibility to reset MARK with the following described SCAN-function. All
information from previously suppressed signals is now reset and you can start with MARK again.
Old device mode: Older analog transceivers are transmitting a weak continuous signal
additional to the digital pulse signal that can have an impact on the digital signal separation. In
such cases, you may nd for a short time that more signals are indicated than actually exist – the
display “number of burials” starts ashing (display of “old device mode”). To suppress (MARK)
these transmitters keep a distance of more than 1 m.
signal with continuous carrier
signal without continuous carrier
IMPORTANT!
The MARK function is subject to physical and technical limitations. This applies to all
transceivers with MARK function! In practice, one might observe performance-reducing limitations which
get intensied by overlapping signals. More information can be found on www.pieps.com.
MULTIPLE BURIALS
PIEPS provides with the PIEPS SAFETY SYSTEM (digital PIEPS beacon and electronic probe
PIEPS iPROBE) a technical 100% solution for multiple burials. By using a digital PIEPS
beacon in combination with the PIEPS iPROBE or iPROBE ONE someone can solve a multiple
burial without any performance-reducing limitations! See also chapter „iPROBE Support“.