84
16.2 Outdoor unit error display
For 9K-24K outdoor unit:
No. Problems
LED2
(Green)
LED1
(Red)
IU display
1 standby for normal O X
2 Operation normally X O
3 Compressor drive board EEPROM error O
E5
4 IPM malfunction or IGBT over-strong current protection
X P0
5 Over voltage or too low voltage protection O O P1
6 Inverter compressor drive error X
P4
7 Inverter compressor drive error
O P4
8
Communication malfunction between main control board
and driver board
P4