Page #13 background image
12
3.2.1 If the water  ow rate is insu cient
In the event that a valve is installed on the cleaner line, open fully to allow the water to flow freely to the cleaner.
Check whether the hoses, fittings and ball joints have leaks.
Before performing the following checks, make sure the booster pump and filter pump are shutdown.
Check that no debris is blocking the in-line filter screen or restricting the water flow.
Clean the skimmer, filter and basket of the pump.
Remove the blue or red restrictor disc from the universal flow restrictor (UWF), see "2.2 I Installing the feed hose
on the suc on port".
3.2.2 If the water  ow rate is too high
Before performing the following checks, make sure the booster pump and filter pump are shutdown.
Position the blue flow restrictor disc (see "2.2 I Installing the feed hose on the suc on port") and check the rotational
speed of the wheel (see "3.2 I Checking the rota onal speed of the wheel").
If the water  ow rate is s ll too high, position the red flow restrictor disc (see "2.2 I Installing the feed hose on the
suc on port") and check the rotational speed of the wheel (see"3.2 I Checking the rota onal speed of the wheel").
If the ow rate remains too high, unscrew the relief valve un l the correct wheel rota onal speed is obtained, see "2.2
I Installing the feed hose on the suc on port".
The relief valve must only be adjusted if a restrictor is installed.