CAUTION
Failure to comply with the following warnings could cause damage to pool equipment or personal injury.
• The Polaris cleaner must be installed and operated as specied.
• This product is intended for use with permanently-installed pools. Do not use with storable pools. A
permanently-installed pool is constructed in or on the ground or in a building such that it cannot be
readily disassembled for storage. A storable pool is constructed so that it is capable of being readily
disassembled for storage and reassembled to its original integrity.
• Clean the lter canister in the Polaris cleaner after each use.
• Do not use the product in your pool if the water temperature is above 95˚ F (35˚ C) or below 55˚ F (13˚ C).
USE OF THE POLARIS ROBOTIC CLEANER IN A VINYL LINER POOL
• Certain vinyl liner patterns are particularly susceptible to rapid surface wear of pattern removal caused
by objects coming into contact with the vinyl surface, including pool brushes, pool toys, oats, fountains,
chlorine dispensers, and automatic pool cleaners. Some vinyl liner patterns can be seriously scratched
or abraded simply by rubbing the surface with a pool brush. Ink from the pattern can also rub off during
the installation process or when it comes into contact with objects in the pool. Zodiac Pool Systems LLC
is not responsible for, and the Limited Warranty does not cover, pattern removal, abrasion or markings on
vinyl liners.
2 Cleaner Specications
General Specications
The general specications for the cleaner are as follows:
Control box
supply voltage
100-240 VAC, 50-60 Hz
Cleaner Supply voltage
30 V DC
Installed load
100 W max
Cable length
Above-Ground - 45ft (14m)
In-Ground - 54ft (16.4m)
Cleaner size
(WxDxH)
14.5 x 11.4 x 11.8 in. (
37 x 29 x 30 cm)
Weight of Cleaner
15.4 lbs. (7 kg)
Filtration
All-purpose lter canister
Cycle lengths
2 hours for Above-Ground pool cycle
2.5 hours for In-Ground pool cycle
The cleaner is a double-insulated product. A double-insulated electrical appliance
is one which has been designed in such a way that it does not require a safety
connection to ground. The basic requirement for double-insulation is that no
single failure can result in dangerous voltage becoming exposed so that it might
cause an electric shock and that this is achieved without relying on an earthed
(grounded) metal casing. This is achieved by having two (2) layers of insulating
material surrounding live parts or by using reinforced insulation. Therefore,
devices having double-insulated construction, such as this cleaner, do not use a
grounded (three-prong) cord/plug.