LED Display Definition Function Value Description
The reactions of the
photocells/ safety
edge/ loop detector
when they detecting
obstacles
Motor Speed
Motor Force
Open Partially
Pre-flashing
The deceleration
setting for gate
moving
Slow
Medium
Fast
Very Fast
3 seconds
6 seconds
9 seconds
12 seconds
15 seconds
18 seconds
The flashing light blinks
when the gate starts to move.
The flashing light blinks 3
seconds before the gate
starts to move.
The gate moves without
deceleration.
The gate moves with
deceleration.
Please the function setting
after F8
F3-1
F3-2
F3-3
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
1. Please the function setting after F8
2. The factory setting is “F3-1”.
1. The function can adjust the
running speed of motor.
2. The factory setting is "F4-4".
1. The function can adjust the
running force of motor to be
compatible with the gate weight.
2. The factory setting is "F5-4".
3. The motor force value:
F5-1: 2A F5-6: 7A
F5-2: 3A F5-7: 8A
F5-3: 4A F5-8: 10A
F5-4: 5A F5-9: 13A
F5-5: 6A
1. The function can adjust the time
of opening partially.
2. The factory setting is "F6-1".
1. The factory setting is "F7-0".
1. The factory setting is "F8-1".
●
The position of safety devices:
Photocell 1 / Photocell 2
Photocell
Safety Edge
Photocell 1
or
Photocell 1
Loop Detector
Photocell 2