8. Specifications
Models MB-3680 MB-3682
Battery Voltage System 12VDC 24VDC
Isolator Setting
Tolerance: ±0.1Vdc for 12Vdc
sys.
Tolerance: ±0.2Vdc for 24Vdc
sys.
LVD
(Disconnect)
LVR (Connect)
LVD
(Disconnect)
LVR(Connect)
10.5V 12.9V 21.0V 25.8V
10 Disconnect Voltage
Selections and 10 Connect
Voltage Selections.
LVD = Cut Out = Disconnect.
LVR = Cut In = Connect
10.9V 13.0V 21.8V 26.0V
11.2V 13.1V 22.4V 26.2V
11.5V 13.2V 23.0V 26.4V
11.9V 13.3V 23.8V 26.6V
12.1V 13.4V 24.2V 26.8V
12.4V 13.5V 24.8V 27.0V
12.6V 13.6V 25.2V 27.2V
12.8V 13.7V 25.6V 27.4V
13.0V 13.8V 26.0V 27.6V
ON / OFF Delay Time For
Isolator Mode
15 Seconds
Protection
Low Voltage Protection (No
Delay)
8.5VDC ±0.5VDC 17VDC ±1.0VDC
Over Voltage Protection 18.5VDC ±0.5VDC 34.5VDC ±1.0VDC
Over Temperature Protection Yes
Protection Current (Start
Point)
150A
Continuous Output Current 100A
Maximum Output Current
(1 Minute)
110A
Operation Current
Consumption (LED ON)
9mA
Standby Current
Consumption (LED OFF)
6mA
Voltage Drop With 100A
(Main Batt. To Aux. Batt)
300mV (Max.)
Operation Temperature
Range
℃℃-40 to +60
Manual Over-ride
Yellow cable (2) to Battery Positive triggers Main & Aux
connection
Indication By LED
LED GREEN = Connect LED No Light = Disconnect
LED RED Protection:
1) Solid RED = Over Voltage (OVP).
2) Slow Flash RED = Over Temperature (OTP).
3) Fast Flash RED = Over Current (OCP).
Dimension (L x W x H) 162x75x50mm (6.3x3.0x2.0 inch)
Weight 486g (17oz)