11
2.2.3 Control Module FC0500-40S-V2 (internal power supply)
Control Module (FC0500-40S-V2) Display Panel
LED Button
Short Press
Display the LED panel for 20sec.
Long Press 1
(between 5 to
10 seconds)
When status LED fast flashes blue , loss the button,
then it is 115200 baud rate of RS485.
When status LED fast flashes orange , loss the button,
then it is 9600 baud rate of RS485.
If a special protocol (except Pylontech Protocol), is
selected follow ‘Long Press 2’, then the baud rate
changing described here is ineffective.
Long Press 2
(more than
10sec)
Communication Protocol Selection, for details please
check with Pylontech service team