8
Basic Parameters
US5000
US5000-B
Nominal Voltage (Vdc) 48
Nominal Capacity (Wh) 4800
Usable Capacity (Wh) 4560
Depth of discharge (%) 95
Dimension (mm) 442*420*161
Weight (Kg) 39.7 40
Discharge Voltage (Vdc) 43.5 ~ 53.5
Charge Voltage (Vdc) 52.5 ~ 53.5
Recommended
Charge/Discharge Current (A)
80*
Max. continuous
Charge/Discharge Current (A)
100*
Peak Charge/Discharge Current (A)
101-120@15min
121~200@15sec
Communication RS485, CAN
Configuration
(max. in 1 battery group)
16pcs
Working Temperature
0°C ~50°C Charge
-10°C ~50°C Discharge
Short current/duration time
<2000A/1ms
Cooling type
Natural
Breaker
No Yes
Protective class
I
IP rating of enclosure
IP20
Humidity
5% ~ 95%(RH) No Condensation
Altitude(m)
4000
Certification TÜV / CE / UL / UN38.3
Design life
15+ Years (25°C /77)
Cycle Life >6,000 25°C
Reference standards
IEC62619, IEC63056,
UL1973, UL9540A, IEC61000-6-2,
IEC61000-6-3, UN38.3
*: The recommended and max. continuous operation current is for a battery cell temperature
within 10~40°C to consider, out of such temp. range will cause a derating on operation current.
Shelf Temperature -20°C ~
60°C