3. When replacing the drainage tank, press the tank firmly into place with both
hands. If the tank is not positioned properly, the “TANK FULL” sensor will be
activated, and the dehumidifier will not operate.
Fig. 7
CONTINUOUS WATER DRAINAGE
The unit features a continuous drainage port. Using a plastic pipe (with an inner diameter
of 10mm) inserts into drain hole (on intermediate plate), reach out from side of water
tank, install it in place, and arrange the drain pipe. The water in the drainage tank can be
continuously drained out from the continuous port on the unit.
Fig. 8
MAINTENANCE
CLEANING THE DEHUMIDIFIER
A. TO CLEAN THE BODY
Wipe it with a soft damp cloth.
B. TO CLEAN THE AIR FILTER
1. Open the inlet grill firstly and remove the air filter.
Fig. 9
2. Clean the air filter
Run a vacuum cleaner lightly over the surface of the air filter to remove dirt. If the
air filter is exceptionally dirty, wash it with warm water and a mild cleanser and dry
thoroughly.