78
DRAINAGE OPTION
OPTION 1 EMPTYING MANUALLY
Notes:
• Do not remove the bucket when unit is in operation or has just stopped.
Otherwise it may cause some water to drip on the floor.
• Do not use the hose if using water bucket to collect water. When the hose is connected,
water will be drained out through it instead of into the bucket.
1
Hold the handles on both sides of the water bucket and pull it out following the
arrow direction. (Attention: Pull out the bucket carefully in case the water may spill
out from the bucket and onto the floor.)
2
Empty the bucket by grasping the handle on the top of bucket with one hand and
grasping the bottom of bucket with the other hand.
3
Replace bucket in the dehumidifier according to the arrow direction.
OPTION 2 GRAVITY DRAIN HOSE
1
Hose is not provided, so user shall prepare it in advance.
[Size: The hose should have an inner diameter of 14mm]
2
Remove bucket from the unit as instructed.
Open the drainage cover and then install the drainage joint on the drainage outlet
tightly along the arrow direction.
G
NOTE!
The drainage joint is with sealing gasket. Before installing the drainage joint,
reinstall the gasket on the drainage joint if it dropped. Otherwise, there will be
water leakage phenomenon.
3
Insert the drainage pipe into the drainage point.
4
78