EasyManuals Logo
Home>Qlima>Air Conditioner>S(C) 33xx

Qlima S(C) 33xx User Manual

Qlima S(C) 33xx
Go to English
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
57
4
57
hang the end in the water. See fig. 15.
Always run the condensation drainage hose under the coolant pipes to prevent that the condensation tray
from overflowing.
CAUTION
Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the unit.
Run the drain hose sloped downward over the whole length to drain out the condensed water
smoothly.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
43
Do not block water flow by a rise.
Do not put the end of drain hose
into water.
Figure 15
9.2 Drain joint installation
Fit the seal into the drain elbow, then insert the drain joint into the base pan hole in the bottom of the
outdoor unit, rotate 90° to assemble them securely. Connect the drain joint with an extension drain hose
(not included). In this way condensed water, which is produced during heating mode of the air conditioner,
can be drained away. See fig. 16.
A
B
Figure 16
Seal
Drain joint
Base pan hole of
outdoor unit
Seal
Drain pipe
10. ELECTRICAL WORK
Connect the air conditioner to a separate group. Ensure that this group has the correct fuse
See following table.
Power voltage supplied should be in the range of 95%~105% of rated voltage on rating table.
The power supply must have an earth leak switch installed.
Ensure the air conditioner is grounded well.
Connect the wires according the attached electrical connection diagram located on the panel of the
outdoor unit. See chapter 11
All wiring must comply with local and national electrical standards and codes and be installed by
qualified and skilled people.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Qlima S(C) 33xx and is the answer not in the manual?

Qlima S(C) 33xx Specifications

General IconGeneral
BrandQlima
ModelS(C) 33xx
CategoryAir Conditioner
LanguageEnglish

Related product manuals