Quest 215 Dual Installation, Operation and Maintenance Instructions
4
www.QuestHydro.com
info@QuestHydro.com
1. Intended Application for Quest 215 Dual
The Quest 215 Dual is designed to operate in temperatures between 56° and 95°F.
In order to eciently control humidity levels, the area in which the dehumidifier is to be operated must be free of
water intrusion or excessive fresh (outside) air infiltration. Before installing the Quest 215 Dual, water intrusion and air
infiltration problems should be addressed or noted in calculations.
2. Registrations
The Quest 215 Dual units conform to unified standard UL 60335-2-40.
3. Specifications
Unit: 4035400 215 Dual
Blower:
(Tested with duct collars on)
526 CFM @ 0.0" WG
495 CFM @ 0.2" WG
458 CFM @ 0.4" WG
Power:
1500 Watts @ 80°F and 60% RH
Supply voltage:
220-240 VAC - 1 Phase - 60 Hz.
Current Draw:
6.9 Amps
Energy Factor:
2.9
Operating Temp:
56°F Min - 95°F Max
Minimum Performance @ 80°F and 60% RH:
Water Removal:
Eciency:
215 Pints/Day
6.1 Pints/kWh
Air Filter:
MERV-11 Size: 16" x 20" x 2"
Power Cord:
10' 14/3 SJTW w/6-15P Plug
Drain Connection:
3/4 Threaded NPT
Dimensions:
Width:
Height:
Length:
Weight:
Unit Shipping
37.875" 42"
21.75" 28.25"
20.25" 24"
150 lbs 170 lbs