5.5 Condensate Pump
The internal condensate pump removes water that collects in the
reservoir.
To replace the condensate pump:
1. Unplug the unit
2. Remove the front housing
3. Unplug the pump wires from the wire harness
4. Remove the condensate hose and the one screw attaching the pump
bracket to the compressor support
5. Replace the pump, hose, wiring, bolts, and housing in the reverse order
5.6 Float Safety Switch
The oat safety switch activates when the water rises too high
in the condensate reservoir. The oat safety switch turns off the
compressor until the water level lowers and disengages the switch.
To replace the oat safety switch
1. Unplug the dehumidier
2. Remove the front housing
3. Unplug the oat safety switch wires from the wire harness
4. Remove the one screw attaching the pump and oat switch
bracket to the compressor support
5. Remove the pump from the reservoir and slide out the oat
switch from under the compressor support
6. Replace the oat, pump, wiring, bolts and housing in the
reverse order
6 Options & Accessories
4026315 Air Filter, Pleated 12: x 12” x 1” MERV-8 (Standard)
4029499 Air Filter, Pleated 12” x 12” x 1” MERV-11
4029521 Intake Flex Duct 12” x 25” Metallize Polyester
4029252 Lay-Flat Duct 10” Round x 250’ Roll
To order, contact Therma-Stor LLC at 1-866-933-7486.
Figure 6: Picture of the oat safety switch
Figure 5: Picture of pump and
oat switch brackets screw.