LEAGEND Battery Tester BA1000 User Manual
8
BA1000
2) Good, Recharge
Good battery but low current, recharge before using.
3) Replace
The battery is near to or already reached the end of the using life, replace battery, otherwise, bigger danger will be followed.
4) Bad Cell, Replace
Battery interior damaged, bad cell or short circuit, replace battery.
5) Charge, Retest
Unstable battery shall be recharged and retested to avoid error. If same test result appears after recharge and retest, the battery is regarded
as damaged, replace the battery.
3.2. Cranking Test
Tester prompts as following:
Starting the engine as prompted, tester will automatically complete the cranking test and display the result.
Start Engine
Cranking Test
RPM Detected
Cranking Test
Health:78% 440CCA
Charge:30% 12.20V
Internal R=7.2mΩ
Rated: 500A
GOOD, RECHARGE
Health:46% 490CCA
Charge:80% 12.68V
Internal R=18.1mΩ
Rated: 500A
Health:0% 0CCA
Charge:20% 10.64V
Internal R=45.2mΩ
Rated: 500A
BAD CELLREPLACE
Health:39% 310CCA
Charge:20% 12.08V
Internal R=30.1mΩ
Rated: 500A
CHARGE-RETEST