P.C.B. SM 20015 boiler settings
2
DIAGNOCODE
SM 20015 ELECTRONIC PRINTED CIRCUIT BOARD
cod. 76655LA
M3
M5
M6
M7
M11
M13
M2
M4
M1
M12
M10
M8
M9
TECHNICAL SPECIFICATION
New generation printed circuit board with easy settings of boiler parameters.
Special features: :
Exclusively for technicians settings
Standard / reduced heating temperature
Water-Hammer prevention function
Short cycling function-3 minutes, heating circuit
Pump overrun function - heating circuit
Pump overrun function - dom. hot water circuit
Minimum output setting
Maximum heating output setting
User settings
On / Off operation
Heating temperature adjustment from 30 to 80 °C
Domestic Hot Water adjustment from 35 to 65 °C
Mode Selection: summer only / winter only /
summer and winter
Lock-out
Normal water pressure
Water deficiency safety switch
Temperature display