RL78 Family VDE Certified IEC60730/60335 Self Test Library
R01AN0749EG0201 Rev.2.01 Page 42 of 50
Mar 04, 2014
5.3.4 Initial March X
Table 26: Initial March X Test Resources
Measurement
Code size 279B
Stack Usage (Module use plus function call) 0B
Data Usage 0B
Execution time (Range = 4KB)
768000 cycles
24mS
5.4 Clock Monitor
The execution time of this function is defined by the frequency of the reference clock therefore the execution time is not
measured.
Table 27: Software Clock Monitor Test Resources
Measurement
Code Size: Program + Data 65B
Data Usage 0B
Stack Usage (Module + function call) 8B
Execution time N/A
Table 28: Hardware Clock Monitor Test Resources
Measurement
Code Size 62B
Data Usage 0B
Stack Usage (Module + function call) 8B
Execution time N/A