Revision 2.3 Page 11 of 14
Warning
Please Note
The specifications of the product detailed on this
Set-Up Guide may change without notice. RDM
Ltd. shall not be liable for errors or for incidental
or consequential damages, directly and indirectly,
in connection with the furnishing, performance or
misuse of this product or document.
ML Multistage Thermostat Installation Guide
www.resourcedm.com
485T Genus/Third Party Compatible
The 485t option shows a value representing the network type. The possible values are:
Value
Network Type
1
Genus compatible (all versions)
2
Not Used in this version
3
Not Used in this version
Genus Compatible
485A Genus
The 485A option shows a value representing either the name of the controller in a Genus compatible network.
The value shown is of the form 05-6. This means the controller would try to log onto a Genus compatible network using the name ‘RC05-
6’.
Once the address has been entered, use the net menu items to go to the “Esc” screen and press enter. This registers the network
address into the controller and the controller will log on at this point.
Gadd
The gAdd option displays (in hexadecimal format) the underlying network address assigned to the controller when it is logged onto the
network.
RLog
The rLog option allows the controller to be logged back onto the network with its current name. The ‘rLog’ message will flash for
confirmation. Press the Enter button to execute the command, Up or Down buttons to cancel.
ClrA
The CLrA option will clear out the network address and name in the controller. The ‘ClrA’ message will flash for confirmation. Press the
Enter button to execute the command, Up or Down buttons to cancel.
To enter this mode, hold the Enter, Up and Down buttons together for approximately 3 seconds until the message CLrA appears on the
display. CLrA is the first option in the menu consisting of the following options:
Display
Option
CLrA
Clear the address/name from the controller
ESC
Exit Setup mode
Pressing the Enter button to select the CLrA option will cause the ‘CLrA’ message to flash for confirmation, if the network type is set to
Genus compatible. Press the Enter button to execute the command, Up or Down buttons to cancel. If the network type is not set to
Genus compatible then the ClrA message will not flash and the ESC option can be used to exit the menu.
SoFt (Software version)
Press “Enter” at this display to show the software version.
OFSt
Probe offsets: - select a channel (1 - 4) and select an offset +/- 20
O
C (68
O
F)
ESC
Press enter at this display to quit out of the menu.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Resource Data Management PR0123-STA and is the answer not in the manual?

Resource Data Management PR0123-STA Specifications

General IconGeneral
BrandResource Data Management
ModelPR0123-STA
CategoryThermostat
LanguageEnglish

Related product manuals