Air
Electrical and Physical Data
13AJN Series
22
Model
Number
13AJN
ELECTRICAL PHYSICAL
Phase
Frequency (Hz)
Voltage (Volts)
Compressor
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Fuse or HACR
Circuit Breaker
Outdoor Coil
Refrig.
Per
Circuit
Oz. [g]
Weight
Rated Load
Amperes
(RLA)
Locked Rotor
Amperes
(LRA)
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM [L/s]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Rev. 5/17/2012
18 1-60-208/230 9/9 46 0.6 12/12 15/15 20/20 7.13 [0.66] 1 1415 [668] 67.4 [1911] 120 [54.4] 128 [54.4]
24 1-60-208/230 13.5/13.5 58.3 0.6 18/18 25/25 30/30 8.43 [0.78] 1 1665 [786] 67.8 [1922] 121 [54.9] 129 [54.9]
30 1-60-208/230 12.8/12.8 64 0.8 17/17 25/25 25/25 8.70 [0.81] 1 2075 [979] 75.0 [2126] 139 [63.1] 147 [63.1]
36 1-60-208/230 16.7/16.7 79 0.8 22/22 30/30 35/35 13.72 [1.27] 1 2540 [1199] 90.6 [2569] 149 [67.6] 157 [67.6]
42 1-60-208/230 17.9/17.9 112 1.2 24/24 30/30 40/40 13.72 [1.27] 1 2540 [1199] 106.0 [3005] 149 [67.6] 157 [67.6]
48 1-60-208/230 21.8/21.8 117 1.2 29/29 35/35 50/50 16.39 [1.52] 1 3290 [1553] 116.1 [3291] 188 [85.3] 192 [85.3]
60 1-60-208/230 26.4/26.4 134 1.2 35/35 45/45 60/60 19.17 [1.78] 1 3380 [1595] 157.2 [4457] 223 [101.2] 234 [101.2]
Electrical and Physical Data
Model
Number
13ACN
ELECTRICAL PHYSICAL
Phase
Frequency (Hz)
Voltage (Volts)
Compressor
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Fuse or HACR
Circuit Breaker
Outdoor Coil
Refrig.
Per
Circuit
Oz. [g]
Weight
Rated Load
Amperes
(RLA)
Locked Rotor
Amperes
(LRA)
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM [L/s]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Rev. 5/17/2012
36 3-60-208/230 10.4/10.4 73 0.8 14/14 20/20 20/20 13.72 [1.27] 1 2540 [1199] 90.6 [2569] 149 [67.6] 157 [67.6]
42 3-60-208/230 13.2/13.2 88 1.2 18/18 25/25 30/30 13.72 [1.27] 1 2540 [1199] 106.0 [3005] 149 [67.6] 157 [67.6]
48 3-60-208/230 13.7/13.7 83.1 1.2 19/19 25/25 30/30 16.39 [1.52] 1 3290 [1553] 116.1 [3291] 188 [85.3] 192 [85.3]
60 3-60-208/230 16/16 110 1.2 22/22 30/30 35/35 19.17 [1.78] 1 3380 [1595] 157.2 [4457] 223 [101.2] 234 [101.2]
Model
Number
13ADN
ELECTRICAL PHYSICAL
Phase
Frequency (Hz)
Voltage (Volts)
Compressor
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Fuse or HACR
Circuit Breaker
Outdoor Coil
Refrig.
Per
Circuit
Oz. [g]
Weight
Rated Load
Amperes
(RLA)
Locked Rotor
Amperes
(LRA)
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM [L/s]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Rev. 5/17/2012
36 3-60-460 5.8/5.8 38 0.35 8/8 15/15 15/15 13.72 [1.27] 1 2540 [1199] 90.6 [2569] 149 [67.6] 157 [67.6]
42 3-60-460 6/6 44 0.8 9/9 15/15 15/15 13.72 [1.27] 1 2540 [1199] 106.0 [3005] 149 [67.6] 157 [67.6]
48 3-60-460 6.2/6.2 41 0.8 9/9 15/15 15/15 16.39 [1.52] 1 3290 [1553] 116.1 [3291] 188 [85.3] 192 [85.3]
60 3-60-460 7.8/7.8 52 0.8 11/11 15/15 15/15 19.17 [1.78] 1 3380 [1595] 157.2 [4457] 223 [101.2] 234 [101.2]
Model
Number
13AYN
ELECTRICAL PHYSICAL
Phase
Frequency (Hz)
Voltage (Volts)
Compressor
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Fuse or HACR
Circuit Breaker
Outdoor Coil
Refrig.
Per
Circuit
Oz. [g]
Weight
Rated Load
Amperes
(RLA)
Locked Rotor
Amperes
(LRA)
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM [L/s]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Rev. 5/17/2012
48 3-60-575 4.8/4.8 33 0.8 7/7 15/15 15/15 16.39 [1.52] 1 3290 [1553] 116.1 [3291] 188 [85.3] 192 [85.3]
60 3-60-575 5.7/5.7 38.9 0.8 8/8 15/15 15/15 19.17 [1.78] 1 3380 [1595] 157.2 [4457] 223 [101.2] 234 [101.2]
NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set.
[ ] Designates Metric Conversions