FILTER RACK FILTER SIZES* INCHES [mm]
MODEL RGTC- RXGF-CC
04 (2) 12 x 20 [305 x 508]
06 (2) 12 x 20 [305 x 508]
07 (2) 12 x 20 [305 x 508]
09 (2) 12 x 20 [305 x 508]
10 (2) 14 x 20 [356 x 508]
FURNACE
WIDTH
IN. [mm]
PLENUM
WIDTH
IN. [mm]
PLENUM ADAPTER
DOWNFLOW
COIL
PLENUM
17
1
/2 [445] 16
1
/4 [413] RXAA-C186 RXAL-B16BU
17
1
/2 [445] 20
1
/4 [514] RXAA-C173 RXAL-B20BU
17
1
/2 [445] 21
5
/8 [549] RXAA-C187 RXAL-B21BU
17
1
/2 [445] 25
1
/4 [641] RXAA-C174 RXAL-B25BU
21
1
/2 [533] 25
1
/4 [641]
RXAA-C175 RXAL-B25BU
21
1
/2 [533] 22
1
/4 [565] RXAA-C176 RXAL-B22BU
24
1
/2 [622] 25
1
/4 [641] RXAA-C177 RXAL-B25BU
24
1
/2 [622] 21
5
/8 [549] RXAA-C187 RXAL-B21BU
21
1
/2 [533] 21
5
/8 [549]
RXAA-C188 RXAL-B21BU
MODEL
RGTC-
BLOWER
SIZE
IN. [mm]
MOTOR
H.P.
[W]
BLOWER
SPEED
CFM [L/s] AIR DELIVERY
EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa]
09
12 x 11
[305 x 279]
3/4
[559]
LOW*
MED-L0
MED-HI
HIGH
1213 [573]
1504 [710]
1734 [819]
2111 [997]
1196 [565]
1474 [696]
1698 [802]
2059 [972]
1179 [557]
1443 [681]
1662 [785]
2007 [948]
1158 [547]
1415 [668]
1621 [766]
1946 [919]
1136 [536]
1387 [655]
1579 [746]
1885 [890]
1108 [523]
1348 [637]
1526 [721]
1821 [860]
0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17]
04
11 x 7
[279 x 178]
1/2
[373]
LOW
MED-LO
MED-HI
HIGH
794 [375]
890 [420]
1110 [524]
1383 [653]
765 [361]
866 [409]
1084 [512]
1350 [638]
735 [347]
842 [398]
1057 [499]
1317 [622]
704 [332]
811 [383]
1023 [483]
1274 [602]
672 [317]
779 [368]
989 [467]
1230 [581]
633 [299]
750 [354]
946 [447]
1171 [553]
594 [281]
721 [341]
902 [426]
1112 [525]
06
11 x 7
[279 x 178]
1/2
[373]
LOW*
MED-L0
MED-HI
HIGH
816 [385]
924 [436]
1164 [550]
1409 [665]
792 [374]
895 [423]
1122 [530]
1367 [646]
767 [362]
866 [409]
1080 [510]
1325 [626]
739 [349]
832 [393]
1044 [493]
1284 [606]
711 [336]
798 [377]
1008 [476]
1242 [586]
686 [324]
754 [356]
966 [456]
1195 [564]
661 [312]
710 [335]
923 [436]
1148 [542]
07
11 x 10
[279 x 254]
1/2
[373]
LOW*
MED-L0
MED-HI
HIGH
1126 [532]
1338 [632]
1555 [734]
1743 [823]
1097 [518]
1309 [618]
1516 [716]
1696 [801]
1068 [504]
1280 [604]
1477 [698]
1649 [779]
1036 [489]
1253 [592]
1440 [680]
1604 [757]
1003 [473]
1225 [579]
1402 [662]
1559 [736]
963 [455]
1185 [560]
1349 [637]
1501 [709]
923 [436]
1145 [541]
1295 [612]
1442 [681]
1079 [510]
1308 [618]
1472 [695]
1756 [829]
10
11 x 10
[279 x 254]
3/4
[559]
LOW*
MED-L0
MED-HI
HIGH
1324 [625]
1617 [764]
1842 [870]
2204 [1041]
1309 [618]
1505 [753]
1812 [856]
2153 [1017]
1294 [611]
1573 [743]
1781 [841]
2102 [993]
1272 [601]
1533 [724]
1728 [816]
2040 [963]
1250 [590]
1493 [705]
1674 [791]
1977 [934]
1221 [577]
1448 [684]
1619 [765]
1905 [900]
1191 [562]
1402 [662]
1564 [739]
1833 [866]
ACCESSORIESDOWNFLOW
PLENUM DATA FOR “A” COILS
Plenum adapters are required in some instances for use on downflow applications
when plenum and furnace size do not match.
VENT TERMINATION KITS CONCENTRIC: HORIZONTAL/
VERTICAL =
RXGY-E03A (US & Canadian Installations)
HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03, RXGY-D04
(US Installations)
RXGY-D02A, RXGY-D03A, RXGY-D04A (Canadian Installations)
RXGY-G02 (US Only)
CONDENSATE PUMP KIT: RXGY-B01
NEUTRALIZER KIT: RXGY-A01
COMBUSTIBLE FLOOR BASE: RXGC-B17
RXGC-B21
RXGC-B24
EXTERNAL FILTER RACK: RXGF-CC
*Filter racks are shipped without filters.
Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.
[ ] Designates Metric Conversions
BLOWER PERFORMANCE DATARGTC MODELS
NOTE: Recommended heating blower speeds are in bold.
*Not allowed for heating speed tap.
NOTE: CFM values represent furnace-only airflow ratings.
NOTE: See Form Number C11-206 for MultiFlex
®
coil data.
FOSSIL FUEL KIT: RXPF-F01 RXPF-F02 (TVA)
6 Rheem Heating, Cooling and Water Heating
FOR HIGH ALTITUDES
NOTE: For Canadian installations only, an optional derate (manifold gas
pressure reduction) method may be used to adjust the furnace for
altitude. See Installation Instructions for more information. This
optional method may NOT be used for U.S. installations.
FOR LEFT SIDE (ALTERNATE) CONDENSATE
DRAIN KIT:
RXGY-H01 (All Models)