PRODUCT INFORMATION
Specications
MANUFACTURER 157k BTU MODELS 199.9k BTU MODELS
Rheem
EcoSense
Paloma/Wai Wela
Ruud
Richmond
RTGH-84DV* and RTGH-84X*
ECOH160DV* and ECOH160X*
PHH-25RDV* and PHH-25ROF*
RUTGH-84DV* and RUTGH-84X*
RMTGH84DV* and RMTGH84X*
RTGH-95DV* and RTGH-95X*
ECOH200DV* and ECOH200X*
PHH-32RDV* and PHH-32ROF*
RUTGH-95DV* and RUTGH-95X*
RMTGH95DV* and RMTGH95X*
Appliance Type Indoor (DV) & Outdoor (X) Indoor (DV) & Outdoor (X)
Electrical Rating 120V/60Hz 120V/60Hz
Type of Gas* NG LP NG LP
Inlet Gas Pressure
Max. (in. of w.c.)
10.5 13.0 10.5 13.0
Inlet Gas Pressure
Min. (in. of w.c.)
4.0 8.0 4.0 8.0
Manifold Pressure
(
in. of w.c. at max. input)
2.5 Indoor
2.6 Outdoor
3.1
3.9 Indoor
4.2 Outdoor
4.6 Indoor
4.7 Outdoor
Maximum Water Supply Pressure (psi) 150 150
Maximum Input Rate (btu/hr) 157,000 199,900
Minimum Input Rate (btu/hr) 11,000 11,000
Recover Rating (gal/hr) 178 226
Shipping Weight (lbs) 81 81
Minimum Activation Flow Rate (gpm) 0.40 0.40
Extinction Flow Rate (gpm) 0.25 0.25
Hot Water Capacity (gpm @ 35°F rise) 8.5 9.5
Hot Water Capacity (77°F rise) 3.9 4.9
Default Temperature Setting (no controller) 120 120
Temperature Default Setting 100 100
Minimum Temperature Setting (°F) 85 85
Efficiency Rating (Energy Factor) 0.94 0.94
Electrical Consumption
Normal 100 W 100 W
Standby 3–5 W 3–5 W
Antifreeze Protection 200 W 200 W
Vent Size (Indoor Only) 2" or 3" 2" or 3"
Water Connections 3/4" NPT 3/4" NPT
Gas Connection 3/4" NPT 3/4" NPT
Water Supply Pressure 14-150 PSI 14-150 PSI
High Altitude (up to 10,000 ft.) Yes Yes
Multiple-Unit Installation Yes Yes
Safety Devices
Overheat Film Wrap, Flame Rod, Water Temperature High-Limit
Switch, Flue Temperature High-Limit Switch
Accessories
Remote Control, Service Valves, Vent Kits, Pipe Cover, EZ Link, MIC-6,
MIC-185, Recess Box**
*N or NG = natural gas and P or LP = liquefied petroleum
** = Outdoor Only