8
Parameter
Number
Description
Number
of
Bytes
Default Min Max Format
1
Heartbeats:
This parameter is the number min-
utes between heartbeats. Heart-
beats are automatic battery reports
on a timer after the last event.
1 70 (0x46) 1 (0x01) 70 (0x46) 1
2
Number of application level retries
attempted for messages either not
ACKed or messages encapsulated
via supervision get that did not
receive a report.
1 1 (0x01) 0 (0x00) 5 (0x05) 2
3
Application Level Retry Base Wait
Time Period: The number base
seconds used in the calculation for
sleeping between retry messages.
1 5 (0x05) 1 (0x01) 60 (0x3C) 3
4
Announcement Audio Volume (for
audio files - should this be lumped
into one of the other volume
settings?)
1 7 0 210 4
5 Key Tone Volume 1 6 0 10 5
6 Siren Volume 1 10 0 10 6
7
Long press emergency duration
(seconds) This parameter allows
a user to configure the duration in
seconds for the hold time required
to capture a long press . This
includes Emergency Buttons +
Mode Buttons (Police, Fire, Medical,
Disarmed, Home, Away)
1 3 2 5 7
8
Long press number pad duration
(seconds) This parameter allows
a user to configure the duration in
seconds for the hold time required
to capture a long press . This
includes Number Pad + Check & X
(0-9, Check, X)
1 3 2 5 8
9
Proximity Display Timeout : Time-
out in seconds when proximity is
detected and no input is received
1 5 0 30 9
10
Button Press Display Timeout : Tim-
eout in seconds when any button
is pressed, but a sequence is not
completed and buttons are no
longer being pressed
1 5 0 30 10
11
Status Change Display Timeout:
Timeout in seconds when indicator
command is received from the
hub to change status
1 5 0 30 11
Configuration Command Class
The Keypad has the following supported configuration parameters.