How the Rinnai Linear models start
Ignition sequence:
1. When the On/Off button is pressed, the infra-red receiver window will pulse green.
2. The combustion fan will start several seconds before the re ignites, to purge the combustion
chamber before the gas ows.
3. The ignition sparker will operate, and as soon as a spark is sensed gas will ow to the pilot
burner, and then to the main burner.
4. When the main burner establishes a ame, the heater will automatically modulate between the
burner settings to achieve and maintain the default set temperature of 22 °C
1
.
Do not unplug or turn off the mains power supply to the re as this will stop the convection fan
from cooling down the unit. The convection fan operates for several minutes after the re has been
turned off.
Power cut or power disruption
If the power is disrupted while the Linear is operating, once the
power has been restored, the re will go into power failure mode,
and 00 (mains power failure) will appear on your smart device.
To reset the re, press the ON/OFF button on the control panel,
remote control, or on the app, twice, to turn the re back on.
1
On initial start-up (no additional buttons pressed), the Linear modulates the ame and heat output to try and maintain
the default temperature setting of 22 °C. If the room temperature starts to climb above 22 °C the Linear will modulate
to its lowest ame and fan setting, but will not turn off. Depending on the size of the room this could mean the room
temperature could steadily rise.
Position of your Rinnai Linear on a wall
If installing the Linear up the wall in an elevated position, air from the convection fan, depending
on the room conguration, could create draughts. This needs to be factored when determining the
location of the re.
Wall surface above the re
The temperature of the wall surface directly above the appliance may get warm and discolour
paint nishes or distort wall coverings. For durability of surfaces, please contact the manufacturer
for their specication. The nish needs to be able to withstand temperatures of up to 65 °C above
ambient.
Fault Code and Fix
00
Probable Cause
Mains power failure.
Description
When power failure is sensed
operation stops.
Action
Reset heater, press the On/Off
button at the fireplace twice.

Other manuals for Rinnai Linear Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai Linear Series and is the answer not in the manual?

Rinnai Linear Series Specifications

General IconGeneral
BrandRinnai
ModelLinear Series
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals