1 Introducon to the instrucons and warnings
This manual is intended only to qualied technician
for installaon.
Any informaon contained in this document may
be considered of interest to the end user.
This manual refers to the supply module for 12Vac
electric lock model H70/EL and must not be used
for dierent products.
RISK OF
ELECTRIC SHOCK
Read the instrucons carefully before performing
the installaon.
To avoid the risk of electric shock and personal
injury, before working with the device, disconnect
the power supply.
Installaon should only be performed by qualied
personnel in accordance with current laws.
Make the connecons with appropriate cables with
the current and voltage required and respect the
features of the product.
WARNING
2 Product descripon
The power supply module of electric lock H70/EL
is designed for just working with the control unit
H70/200AC.
The module allows to power an electric lock of 12Vac
of maximum power 16VA. Besides it also allows to
easily connect a ashlight of 230Vac (R92/LR1 and
R92/LR2) and to protect it by a fuse. The funconal
scheme is represented in gure 3.
EN
3 Technical features of the product H70/EL
POWER SUPPLY 230Vac 50Hz
CURRENT ABSORPTION 350mA max
ELECTRIC LOCK TENSION 12Vac
MAX. POWER ELECTRIC LOCK 16VA
FLASHLIGHT TENSION 230Vac 50Hz
MAX. POWER FLASHLIGHT 40W
WORKING TEMPERATURE -20°C ÷ +60°C
PROTECTION GRADE IP 00
PRODUCT SIZE dimension in mm. 63 x 101 x 40 WEIGHT: 465 g
4 Installaon
Fix the module through the screws inside the box of
the control unit H70/200AC in the posion indicated
in the gure 2.
Make the connecons with the central unit, to
the electric lock and eventually to the ashlight
following the scheme as represented in gure 1.
The fuse F1 (1A delayed) protects the transformer
and the ashlight, while the fuse F2 (2A delayed)
protects the electric lock.
5 Disposal
The product must be always uninstall by the technical
and qualied sta, using appropriate processes for the
correct removal of the product.
This product is made of dierent materials, some
of them could be recycled others must be disposed
through recycling or disposal systems established by
local regulaons for this product.
It is forbidden to dispose the product into the house
garbage. Make the “separate collecon” for disposal
according to the methods established by local
regulaons; otherwise return the product to the seller
when you buy the new equivalent product.
Local regulaons may provide for heavy penales for
illegal disposal of this product.
Cauon: some parts of the product may
contain pollutants and hazardous, if
thrown they may cause dangerous eects
to the environment and to the human
health.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roger Technology H70 Series and is the answer not in the manual?

Roger Technology H70 Series Specifications

General IconGeneral
BrandRoger Technology
ModelH70 Series
CategoryControl Systems
LanguageEnglish

Related product manuals