Appendices
Troubleshooting Other Problems
Parameters specified with pedal
assign can’t be controlled
Could the effect be switched off?
To control a parameter using the expression pedal or
CTL pedal, make sure the effect that contains the
parameter you intend to control is switched on.
Is something other than “Assignable” selected for the
Sub CTL 1,2 Function or Sub EXP Pedal Function
setting?
When operating a controller connected to the SUB EXP
PEDAL/SUB CTL 1, 2 jack, set the Sub CTL 1, 2 Function
(p. 55) or Sub EXP Pedal Function (p. 56) to
“Assignable.”
Do the MIDI channel settings of both devices match?
Make sure that the MIDI channels of both devices match
(p. 80).
Do the controller number settings of both devices match?
Make sure that the controller number of both devices
match (p. 60).
MIDI messages are not transmitted/
received
Are the MIDI cables broken?
Try another set of MIDI cables.
Is the GT-8 correctly connected to the other MIDI device?
Check connections with the other MIDI device.
Do the MIDI channel settings of both devices match?
Make sure that the MIDI channels of both devices match
(p. 80).
When you send messages from the GT-8, make sure the
GT-8 is set to the settings appropriate for sending data.
Check the on/off status (p. 80) for transmission of
program change messages and the settings for the
controller numbers to be transmitted (p. 81) .
Restoring the Factory
Settings (Factory Reset)
Restoring the GT-8 to the settings made at the factory is
referred to as “Factory Reset.”
Not only can you return all of the settings to the values in
effect when the GT-8 was shipped from the factory, you can
also specify the range of settings to be reset.
fig.09-060
1.
Turn off the power.
2.
While holding down PREAMP/SPEAKER On/Off
button and [TYPE VARIATION], turn on the power.
The Factory Reset range setting screen appears in the
display.
fig.09-070d
* To cancel Factory Reset, press [EXIT].
3.
Press PARAMETER [ ] [ ] to move the cursor,
and rotate the PATCH/VALUE dial to specify the range
of settings you want to restore to factory settings.
4.
If you want to proceed with the factory reset, press
[ENTER].
The specified range of data will be returned, and return
to the Play screen.
value
Explanation
System
System parameters, Harmonist scales, Auto Riff phrases, and
Preamp/Speaker, Overdrive/Distortion, and Wah Custom Edit
parameter settings
Quick
Content of the Settings Made with User Quick Setting
#1-1–#35-4
Settings for Patch Number 1-1 through 35-4
4
3123
The range of data you wish to factory reset
GT-8_e.book 90 ページ 2007年6月29日 金曜日 午後3時55分

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roland GT-8 and is the answer not in the manual?

Roland GT-8 Specifications

General IconGeneral
BrandRoland
ModelGT-8
CategoryRecording Equipment
LanguageEnglish

Related product manuals