H1 Series
connect the negative connector to the negative side of the solar side. Be sure to connect
them in right position.
Connecting Procedures:
(1)Tighten the lock screws on positive and negative connector.
(2)Use specified strip tool to strip the insulated enclosure of the positive
and negative cables with appropriate length.
1. Positive Cable 2. Negative Cable
Figure 5.7 Connecting Cables
(3)Feed the positive and negative cables into corresponding lock screws.
(4)Put the metal positive and negative terminals into positive cable and
negative cable whose insulated enclosure has been stripped off, and crimp
them tightly with a wire crimper. Make sure that the withdrawal force of the
pressed cable is larger than 400N.
(5)Plug in the pressed positive and negative cables into relevant insulated
enclosure, a “click” should be heard or felt when the contact cable assembly
is seated correctly.
(6)Fasten the lock screws on positive and negative connectors into
corresponding insulated enclosure and make them tight.
(7)Connect the positive and negative connectors into positive and negative
DC input terminals of the inverter, a “click” should be heard or felt when the
contact cable assembly is seated correctly.