EasyManuals Logo
Home>SAJ>Inverter>R6 Series

SAJ R6 Series User Manual

SAJ R6 Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
R6 Series
- 12 -
3.4 Datasheet
R6-15K/17K/20K/22K/25K-T2-32
Model
R6-15K-T2-3
2
R6-17K-T2-3
2
R6-20K-T2-3
2
R6-22K-T2-3
2
R6-25K-T2-
32
Input (DC)
Max. PV Array Power [Wp]@STC
22500
25500
30000
33000
37500
Max. Input Voltage [V]
1100
MPP Voltage Range [V]
180-1000
Nominal Input Voltage [V]
600
Start-up Voltage [V]
200
Max. Input Current [A]
32/32
Number of MPP Trackers
2
Number of Strings per MPP Tracker
2/2
Output (AC)
Rated AC Output Power [W]
15000
17000
20000
22000
25000
Max. Apparent Power [VA]
16500
18700
22000
24200
25000
Rated AC Output Current
[A]@230Vac
21.7
24.6
29
31.9
36.2
Max. AC Output Current [A]
25.0
28.3 33.3
36.7
41.7
Nominal AC Voltage/ Range [V]
220(F-N)/380(F-F); 180-280(F-N)/312-485(F-F)
Nominal AC Grid Frequency/ Range [Hz]
50, 60/44-55, 54-65
Total Distortion Harmonic [THDi]
< 3%
Power Factor
0.8 leading0.8 lagging
Feed-in Phases/AC Connection Phases
3/3
Efficiency
Max. Efficiency
98.8%
Euro Efficiency
98.5%
Protection
DCI Monitoring
Integrated
GFCI Monitoring
Integrated
Grid Monitoring
Integrated
AC Grounding Detection
Integrated
AC Short-Circuit Protection
Integrated
DC Insulation Resistance Detection
Integrated
DC Surge Protection
Type III

Questions and Answers: