2. SPECIFICATIONS
2-1. Unit Specifications
Indoor Unit KHS3082
Outdoor Unit CH3082
< 230V >
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 80°F D.B. / 67°F W.B.
Outdoor air temperature 95°F D.B. / 75°F W.B.
Heating: Indoor air temperature 70°F D.B.
Outdoor air temperature 47°F D.B. / 43°F W.B.
Vertical
dB-A
dB-A
Indoor : Hi/Me/Lo/Qt*
Outdoor : Hi
Air Filter
Compressor
Refrigerant / Amount charged at shipment Ibs (g)
Refrigerant Control
( 14,000 to 33,000 )
( 4.1 to 9.7 )
16.5
3,290
( 5.0 to 16.5 )
( 1,000 to 3,290 )
15.3
3,070
( 4.5 to 15.3 )
( 900 to 3,070 )
30,600
9.0
33,000
9.7
( 10,900 to 30,600 )
( 3.2 to 9.0 )
Shipping Volume
Cooling Heating
18,600
12,000
Net
Shipping
Package Dimensions
Weight
Height × Width × Depth
Height × Width × Depth
Ibs (kg)
Ibs (kg)
cu.ft (m
3
)
(mm)
inch
(mm)
230V Single-Phase 60Hz
inch
-
-
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
Sensible Capacity
Latent Capacity
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tube Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
32.0
39.7
4.59
(14.5)
(18.0)
(0.13)
185.2
207.2
15.88
(84.0)
(94.0)
(0.45)
42-3/8 × 40 × 16-3/8
(1,076 × 1,016 × 416)
(300 × 1,065 × 230) (910 × 940 × 340)
12-7/32 × 44-7/8 × 14-31/32
(310 × 1,140 × 380)
Outdoor UnitIndoor Unit
11-13/16 × 41-15/16 × 9-1/16 35-13/16 × 37-1/32 × 13-3/8
3/8 (9.52)
5/8 (15.88)
ft (m)Max. allowable tubing length at shipment
Flare Type
164 (50)
49 / 44 / 39 / 3249 / 44 / 39 / 32
5555
R410A / 6.5 (2,950)
Electric Expansion Valve
Washable, Anti-Mold
DC Twin Rotary (Inverter)
Manual
Auto
Timer
Indoor / OutdoorFan Speeds
24-Hour ON or OFF Timer, 1-Hour OFF Timer
Auto and 3 steps / Auto (Hi, Me, Lo)
Airflow Direction (Indoor) Horizontal
Controls / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
HSPF
Compressor Locked Rotor Amperes
BTU/Wh
Optional / Air Clean Filter
BTU/h
Performance
- 9.0
%Power Factor 87 87
A 31.0
Voltage Rating
BTU/h
kW
Total Capacity
BTU/h
SEER BTU/Wh 16.0 -
630 (1,070) 671 (1,140)Air Circulation (High) ft
3
/min (m
3
/h)
9.57 -Moisture Removal (High) Pints/h
COP W/W - 3.15
EER BTU/h/W 9.30 -
Fuse or Circuit Breaker Capacity A35