Check the electrical connection cables for damage
regularly.
Ensure that the connection cables are disconnected
from electrical power when checking for damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
AC motor
The mains voltage must be 220 - 240 V~.
Extension cables up to 25 m long must have a
cross-section of 1.5 square millimetres.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
Type of current for the motor
Machine data - type plate
Engine data - type plate
Connection type Y
If the mains connection cable of this device is dam-
aged, it must be replaced by the manufacturer, their
service department or a similarly qualied person to
avoid dangers.
11. Cleaning, maintenance, storage
and ordering spare parts
m Attention!
Pull out the mains plug before carrying out any clean-
ing and maintenance work! Risk of injury from electric
shock!
m Attention!
Wait until the equipment has cooled down completely!
Danger of burning!
m Attention!
Always depressurise the equipment before carrying
out any cleaning and maintenance work! Danger of
injury!
Attention! The manometer has not been o󰀩cially cal-
ibrated!
After inating, please check the air pressure with a
calibrated device.
9.6 Using the air blow gun( g. 4)
You can also use the air blow gun (15) to clean out cav-
ities and to clean soiled surfaces and work equipment.
Always wear protective goggles when doing so!
9.7 Using the adapter set( g. 4)
The adapter set enables you to use the following addi-
tional capabilities of the tyre ination device:
Pumping up balls with the help of the ball needle (12).
The valve adapter (14) enables bicycle tyres to be in-
ated.
Filling pools, air mattresses or boats with the help of
the additional adapter (13).
10. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer‘s mains connection as well as the ex-
tension cable used must also comply with these
regulations.
When working with spray attachments and during tem-
porary use outdoors, the device must be connected to
a residual current circuit breaker with a trigger current
of 30 mA or less.
Damaged electrical connection cable.
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
Pressure points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been improp-
erly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.

Table of Contents

Other manuals for Scheppach HC06

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Scheppach HC06 and is the answer not in the manual?

Scheppach HC06 Specifications

General IconGeneral
BrandScheppach
ModelHC06
CategoryAir Compressor
LanguageEnglish

Related product manuals