LC-40/46LE810E, LC-40/46LX810E
6 – 14
Table 1. Concrete flashing pattern
*2: It depends on the system. The power supply error suitable for the product is defined.
*3: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
*4: If the boot section is abnormal, there is no flashing (flashing disabled).
MONITOR ERR STBY table
Item
Expression for a rough content Expression for Details
Cause
low-speed
blinking
high-speed
blinking
low-speed
blinking
high-speed
blinking
Lamp system failure Flashes once — Flashes once Flashes once Lamp error
Power PWB failure Flashes twice — Flashes twice Flashes once Power Error 1 AC_DET error (*2)
(Power failure, etc.) Flashes twice Power Error 2 UR+13.5V error (*2)
Flashes 3 times Power Error 3 D3.3V error (*2)
Flashes 5 times Panel power supply error
Main PWB failure Flashes 3 times — Flashes 3 times Flashes once Initial communication error
(Communication Flashes twice Start-up confirmation communication error
failure, etc.) Flashes 3 times Regular communication error
Flashes 5 times Other communication error
Others Flashes 4 times — Flashes 4 times Flashes once Temperature error
Flashes twice Sync error
Flashes 3 times Notification from the main microprocessor
(*3)
Upgrade executing smoothness
changes.
— — — Version upgrading
Upgrade completion a staircase
pattern.
— — — Version upgrade succeeded
Upgrade failed — Flashing
(Continuous)
— — Version upgrade failed
ROM data failure — Flashing
(Continuous)
— — Start-up after failing version upgrade (*4)
Outline: Communication/Power failure detected by the monitor microprocessor (IC2002) is stored on EEPROM, states can be confirmed in the
adjustment process mode.
Location: Page 1/21 of the adjustment process mode: MONITOR ERR CAUSE “0” if there is no error. It is cleared to 0 on the page (2/21) of the
adjustment process mode.
Display Error description
02 Start-up communication error 2 Initial communication from the main CPU is not received.
03 Start-up communication error 3 Only the initial communication is received.
04 Start-up communication error 4 Until panel information request reception
05 Start-up communication error 5 Until initialization completion reception
06 Start-up communication error 6 Until version notification transmission
07 Start-up communication error 7 Until start-up information notification transmission
08 Start-up communication error 8 Until start-up information response reception
09 Start-up communication error 9 Until time-out setting reception
0A Communication error A REQ time-out
0B Communication error B Restart time-out during the beginning of time acquisition start-up
0C Communication error C Ending sequence time-out
0D Communication error D Preset start-up time-out during completion
0E Communication error E Download start-up time-out
0F Communication error F Time acquisition time-out
11 Communication error H Regular communication time-out
16 Panel-related error Lamp failure
1A Other error 2 Monitor temperature failure
1D Power supply error 1 PS_ON (AC_DET) failure
1E Power supply error 2 D_POW (DET_13V) failure
1F Power supply error 3 D_POW (DET_D3V3) failure
21 Power supply error 5 Panel power failure
23 Other error 3 Error standby request from the main CPU