EasyManuals Logo
Home>Shinkawa>Monitor>VM-5U

Shinkawa VM-5U User Manual

Default Icon
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
8. FUNCTIONAL DIAGRAM VM-5S
-59-
8-2 FUNCTIONAL BLOCK DIAGRAM
1 Input amplifier
Buffer amplifier for input signals.
2 LPF
Cuts off the high frequency range.
3 HPF (Enabled for VM-5K, 5U, 5B and 5M)
Cuts off the low frequency range.
4 Integrator (Enabled for VM-5U, 5B and 5M)
Integrates the input signal to convert acceleration to velocity or velocity to displacement.
5 Output amplifier
Buffer amplifier for monitor output from the BNC connector on the monitor front panel and to
the terminal block on the rear panel (VM-5G Single Unit Instrument Rack, VM-5Y Relay
Module Unit).
6 Integrator (Enabled for VM-5T, 5D, 5N, 5E, 5A, 5L, 5J and 5C)
Integrates the PWM (pulse width modulation) signal, and converts it to a DC voltage
proportional to the measured value.
7 Zero shift
(Enabled for VM-5T, 5D, 5N, 5E, 5A, 5L and 5J. For VM-5C, only enabled on CH2.)
The input signal is zero-shifted by the DC voltage output from the integrator.
8 Programmable Gain Amplifier
Converts the input signal to the voltage level required by the detection circuit.
9 Detection circuit (Enabled for VM-5K, 5U, 5B and 5M)
Detects the input signal, and converts it to a DC voltage proportional to the vibration.
• P-P detection Peak-to-peak detection
• AVE detection Average value detection
• RMS detection (option) Effective value detection