4.5 Diagnostics of defects
4.5.1 Mechanical causes
Breakdown
Possible cause Remedy precaution
Scratchy noise
Bearings are
overheated
Excessive
temperature of
Radial vibration
Axial vibration
Excessive noise
•
Contact of rotor or shaft with
solid parts of machine appears
Find and eliminate cause
•
Limited access of air, excessive
amount of dust in winding,
dust in cooler ducts
Perform check of access of air,
pollution of winding, check cooler
•
Polluted or blocked air filter (if
it is equipped)
Filter exchange, if need to clean
•
Cooler function gets worse
(goes for design with water
cooler)
Clean cooler with regards to
operational instructions, check
amount of cooling medium, vent
cooler
•
Unbalance on rotor
Contact producer and require
balancing
•
Unbalance in coupling Rebalancing
•
Transfer of vibration from
linked machine
Check of linked machine
• •
Badly fixed generator in
foundation or changes in
foundation
Level machine, check foundation,
and tightening of generator
• •
Resonance with foundation Strengthen foundation
•
Lack of lubricant in bearing Check amount of lubricant in bearing
•
Bearing is overloaded
Check tightening, levelling and
clamping of machine
•
Damaged or badly worn out
bearing
Perform exchange
Tab. 9 Mechanical causes