Document No. 129-363
Quick Reference Guide
May 13, 2015
Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models
as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners.
© 2015 Siemens Industry, Inc.
Building Technologies Division
1000 Deerfield Parkway
Buffalo Grove, IL 60089
USA
Your feedback is important to us. If you have
comments about this document, please send them
to SBT_technical.editor.us.sbt@siemens.com
Document No. 129-363
Printed in the USA
Page 3 of 3
Night Override
1. Remove passkey (if present) from MMI port.
2. To select day operation: Press
.
Viewing Point Descriptions
1. Insert passkey in MMI port.
2. To select points: Press
or .
3. To exit: Remove the passkey.
Viewing/Commanding Point Values
1. Insert passkey in MMI port.
2. To select a point: Press
or .
3. To view a point's value: Press
.
4. To view point command cursor: Press
or .
5. To select a character: Press
.
6. To change a character: Press
or .
7. To cancel changes: Remove the passkey.
8. To save changes: Press
.
9. To return to View Pt. Descript: Press
.
10. To exit: Remove passkey.
Releasing Points from Override and/or
Resetting to Factory Default Values
1. Insert passkey in MMI port.
2. To select a point: Press
or .
3. To view a point's value: Press
.
4. To view the point command cursor: Press
or .
5. Press
until * or override symbol (#) is selected.
6. To release the point: Press
or .
7. To cancel changes: Remove the passkey.
8. To confirm release: Press
.
9. To exit: Remove the passkey.
Setting Display Options
NOTE: Point 00 (SETUP) exist only in the sensor.
1. Insert passkey in MMI port.
2. Press
or , scroll to Point 00, and press .
a. TEMP (temperature)
To display TEMP (YES/NO): Press
or .
b. CRPT (critical point)
To go to CRPT command line: Press .
To select a point number: Press
or .
To turnoff CRPT display: Select Point 00.
c. UNITS
Press
and view the UNITS screen.
To select English/Metric: Press
or .
3. To exit and save changes: Press
.
4. Remove the passkey.