Adding Constants
70
S7-400 Instruction List
A5E00267845-01
Adding Constants
Adding integer constants and storing the result in ACCU1. The status word is not affected.
Instruc-
Address
Description
Length
in
Execution Time in s
Instruc-
tion
Address
ID
Description
Length
in
Words
CPU 412 CPU 414 CPU 416 CPU 417
+ i8 Add an 8-bit integer constant 1 0.1 0.06 0.04 0.03
+ i16 Add a 16-bit integer constant 2 0.125 0.075 0.05 0.042
+ i32 Add a 32-bit integer constant 3 0.185 0.11 0.075 0.062