Chapter 4
Technical Specifications
RUGGEDCOM RMC30
Installation Guide
20 Supported Networking Standards
f
Typical distance. Dependent on the number of connectors and splices.
g
RMS 1 minute.
Section4.3
Supported Networking Standards
Parameter 10Base-FL 100Base-FX Notes
IEEE 802.3 Yes No 10Base-T
IEEE 802.3x Yes No Yes No Full Duplex, Flow Control
Section4.4
Operating Environment
Parameter Range Comments
Ambient Operating Temperature -40 to 85 °C
(-40 to 185 °F)
Measured from a 30 cm (12 in) radius surrounding the center of the
enclosure.
Ambient Relative Humidity 5% to 95% Non-condensing
Ambient Storage Temperature -40 to 85 °C
(-40 to 185 °F)
Section4.5
Mechanical Specifications
Dimensions Refer to Chapter5, Dimension Drawings
Weight 0.68 kg (1.5 lbs)
Ingress Protection IP40 (1 mm or 0.04 in objects)
Enclosure 21 AWG Galvanized Steel