Page #11 background image
2 Engineering
Securely Connecting RTU3041C to TeleControl Server Basic
Entry ID: 109739240, V3.0, 07/2021
11
© Siemens AG
2021 All rights reserved
The following table provides an overview of all IP addresses used in this example.
Assignment of static IP addresses is assumed.
Table 2-1
Component
IP address
Subnet mask
Description
PG/PC "TCSB"
192.168.2.11
255.255.255.0
TeleControl Server
Basic
Engineering PG/PC
WAN (X1)
172.16.1.50
LAN (X2)
192.168.2.10
255.255.0.0
255.255.255.0
SINEMA Remote
Connect Server
PG/PC "Client"
192.168.5.12
255.255.255.0
SINEMA Remote
Connect Client
OPC UA Client
RTU3041C
192.168.0.3
192.168.2.3
255.255.255.0
Access to WBM
SINEMA Remote
Connect Server
172.116.1.60
255.255.0.0
WAN IP address
SINEMA Remote
Connect Clients
172.30.0.1-
172.30.255.254
255.255.0.0
Virtual IP
addresses (defined
IP range)
Note
If you have configured several interface cards on your PC or server (e.g., PG/PC
"TCSB"), and you cannot configure a default gateway for the TCSB, add a static
route to the Windows routing table.
1. Start Command Prompt (Desktop app) as administrator.
2. For example, enter the following command:
Route add 172.30.0.0 MASK 255.255.0.0 192.168.2.10
3. Press enter.
Result:
172.30.0.0: Target subnet (VPNs defined IP range)
192.168.2.10: SINEMA RC Server (LAN)