■Process data
Process data is the data which is exchanged periodically between the master and device.
This product process data consists of switch output status, error diagnostics and pressure gauge
measurement value.
(Refer to the table below.)
2 Diagnosis
0: Normal 1: Abnormal
Set with the index 0x03EB.
∗: Refer to the table (diagnostic information).
3 to 15
Pressure gauge
measurement value
Unsigned 13bit
∗: Refer to the table (Unit specification and pressure gauge measurement value (PD)).
Pressure gauge measurement value (PD)
•The process data of this product is Big-Endian type.
When the transmission method of the upper communication is Little-Endian, the byte order will be changed.
Refer to the table below for the Endian type of the major upper communication.
Upper communication protocol
Such as PROFIBUS and PROFINET
Such as EtherNET/IP, EtherCAT and CC-Link IE Field.
○Diagnostic information
This product can detect the device error by diagnostic bit in the process data.
Monitoring items of the device condition can be set by the diagnostic information selection [F_0].
Set value Content
ALL
All errors
Diagnostic bit will be "1: ON" when either of the following errors is generated.
•Product internal failure
•Residual pressure error
•Exceeding upper limit of the temperature in the product
•Out of the rated pressure (when HHH and LLL are generated.)
PrES
Pressurizing error
Diagnostic bit will be "1: ON" when the following error is generated.
•Out of the rated pressure (when HHH and LLL are generated.)
oFF
Unused
Disgnostic information is not used.