○Error indication function
This function is to display error location and content when a problem or an error occurs.
A load current of switch output is 80 mA
or more.
Turn the power off and remove the
output factor for the over current.
Then turn the power on.
During zero clear operation, pressure
over 10%F.S. is applied. After 3 s, the
mode will reset to the measurement
mode. ±1 digit of the zero clear range
varies with individual product
differences.
Perform zero clear operation again after
restoring the applied pressure to an
atmospheric pressure condition.
Pressure has exceeded the upper limit
of the set pressure range.
Reset applied pressure to a level within
the set pressure range.
Pressure has exceeded the lower limit
of the set pressure range.
Displayed in the case of an internal data
error.
Turn the power off and turn it on again.
If resetting fails, an investigation by
SMC Corporation will be required.
If the error can not be reset after the above measures are taken, then please contact SMC.