EasyManuals Logo
Home>SMC Networks>Controller>ITV1000 series

SMC Networks ITV1000 series User Manual

SMC Networks ITV1000 series
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
1
Electro-Pneumatic Regulator
Series
ITV1000/2000/3000
Standard Specifications
Model
Maximum supply pressure
Minimum supply pressure
24 VDC ± 10%, 12 to 15 VDC
Set pressure +0.1 MPa
Set pressure range
0.2 MPa
Input signal
Input
impedance
Output pressure
display
Weight
Accuracy
Minimum unit
ITV10
씲씲
ITV20
씲씲
ITV30
씲씲
Ambient and fluid temperature
Enclosure
1.0 MPa
0.005 to 0.1 MPa 0.005 to 0.5 MPa 0.005 to 0.9 MPa
ITV
How to Order
Pressure range
3 0 Q10
1
3
5
0.1 MPa
0.5 MPa
0.9 MPa
S01 2
Pressure display unit
2
3
4
5
MPa
kgf/cm
2
bar
PSI
kPa
Input
signal
0
1
2
3
4
Current 4 to 20 mA (Sink type)
Current 0 to 20 mA (Sink type)
Voltage 0 to 5 VDC
Voltage 0 to 10 VDC
Preset input
Cable connector type
S
L
N
Straight type 3 m
Right angle type 3 m
Without cable connector
Bracket
B
C
Without bracket
Flat bracket
L-bracket
Monitor output
0
1
2
3
None (for preset input)
Analogue output 1 to 5V DC
Switch output/NPN output
Switch output/PNP output
Thread type
N
T
F
Rc
NPT
NPTF
G
Port size
1
2
3
4
1/8 (1000 type)
1/4 (1000, 2000, 3000 type)
3/8 (2000, 3000 type)
1/2 (3000 type)
Power supply
voltage
0
1
24 VDC
12 to 15 VDC
Model
1
2
3
1000
2000
3000
JIS Symbol
0 to 50°C (with no condensation)
IP65
Approx. 250 g (without options)
Approx. 350 g (without options)
Approx. 645 g (without options)
4 to 20 mA, 0 to 20 mA (Sink type)
0 to 5 VDC, 0 to 10 VDC
4 points
250 or less
Approx. 6.5 k
Approx. 2.7 k
Linearity
Hysteresis
Repeatability
Sensitivity
Temperature characteristics
Power supply
Voltage
Current
consumption
Within ±1% (full span)
Within 0.5% (full span)
Within ±0.5% (full span)
Within 0.2% (full span)
Within ±0.12% (full span)/°C
±3% (full span)
MPa: 0.01, kgf/cm
2
: 0.01, bar: 0.01, PSI: 0.1 , kPa: 1
NPN open collector output: Max. 30 V, 30 mA
PNP open collector output: Max. 30 mA
Power supply voltage 24 VDC type: 0.12 A or less
Power supply voltage 12 to 15 VDC type: 0.18 A or less
Switch output
Analogue output
Straight type Right angle type
ITV105
ITV205
ITV305
ITV103
ITV203
ITV303
ITV101
ITV201
ITV301
1 to 5 VDC (Load impedance: 1 k or more)
Option
Option
Option
Option
Option
CE compliance
Q
CE compliant
Current type
Voltage type
Preset input
Current type
Voltage type
Preset input
Note 2)
Output signal
(monitor
output)
Note 3)
Note 4)
Note 1) Please refer to graph 1, relation to the differences between the set pressure and input.
Additionally, refer to the page 18 for the set pressure range by units of standard measured pressure.
Additionally, refer to page 18 as maximum set pressure differs on unit of standard measure.
Note 2) 2-wire type 4 to 20 mA is not available. Power supply voltage (24 VDC or 12 to 15 VDC) is required.
Note 3) Select either analogue output or switch output.
Further, when switch output is selected, select either NPN output or PNP output.
Note 4) The minimum unit for ITV205 is 1PSI.
Note 5) The above characteristics are confined to the static state. When air is consumed on the output side,
the pressure may fluctuate.
Note 1)
Input/output characteristics chart
Input signal (%F.S.)
0
0 100
Output pressure
(MPa)
This range is outside
of the control (output).
0.005 MPa
Rated pressure

Other manuals for SMC Networks ITV1000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks ITV1000 series and is the answer not in the manual?

SMC Networks ITV1000 series Specifications

General IconGeneral
BrandSMC Networks
ModelITV1000 series
CategoryController
LanguageEnglish

Related product manuals