OIL MAINTENANCE
10
Check
the oil periodically for clarity. Replace oil if it appears milky or if debris is present, or every 6 months,
or 100 hours of runtime, whichever comes rst. In harsh environments such as high heat or high humidity,
you will need to replace the oil more frequently.
CAUTION! TO PREVENT INJURY FROM BURNS: Allow Compressor Pump to cool before changing the
oil.
1. Place a container under the Oil Drain Plug.
2. Remove the Oil Fill Plug to allow air ow into the Pump.
3. Remove the Oil Drain Plug, allowing the oil to drain into the container.
4. When the oil is completely drained from the Pump, replace the Oil Drain Plug.
5. Fill the Pump with new SAE 30W, non-detergent, Air Compressor Oil to the FULL level on the Oil Sight
Glass.
6. Replace and tighten the Oil Fill Plug.
7. Discard the old oil according to local, state and federal regulations.
AIR FILTER MAINTENANCE
Check the Air Filters weekly to see if they need replacement. If working in dirty environments, you may need
to replace the lters more often.
1. Remove the Air Filter Front Covers.
2. Remove the Air Filter Elements.
3. Replace with new Air Filter Elements
4. Replace the Covers.