• The discharge line (min. 19mm(3/4”)) must be connected to the discharge connector
2
either directly or with the aid of a standard adaptor
8
and clamp
7
.
• With the right couplings it is also possible to use a 13mm(1/2”) delivery hose. The smaller
delivery hose results in a lower delivery rate.
• During the priming operation, fully open any shut-off mechanisms(spray nozzles, valves, etc.)
in the discharge line so that the air can escape without obstruction.
Preparing the discharge line
5. BEFORE FIRST USE
6. OPERATION
DANGER! Risk of injury due to electric shock.
Warning! Do not plug in before installation is fully completed!
Setting up your pump
• Place the pump on flat firm surface to ensure safe operation.
• Remove the connectors caps
1
from the connectors
2
&
3
, and store them.
Connecting the intake line
• Screw the standard connector
8
onto the suction connector
3
.
• Assemble the intake line using a standard connector
8
and clamp
7
. Make sure the
assembly is tight enough as a leaking intake line will draw in air instead of water.
• If the water is not so clear, add a filter between the suction connector and intake line.
116