GTS Technical Manual
14. March 2014 Edition: V1.00/2014 5-34
Copyright © 2014, Diversey Care
05.72.27 mangetic valve & water outlet - valve unit - 30_45_V1.00.fm
5.5 Magnetic valve & water outlet
5.5.7 Removing of valve unit
Picture 48: Valve unit
• Remove the two nozzles (30:06/105, 45:07/105) and (30:06/
106, 45:07/106) from the valve unit (30:06/103, 45:07/103).
Remarks
Use the additional tool (30:06/142, 45:07/142) to remove the two
nozzles.
• Open fresh water tank according to chapter REMOVING OF FRESH
WATER TANK ASSEMBLY.
Ensure that no water is in the fresh water system before you
disconnect the hoses.
• Remove brush cover according to chapter REMOVING OF BRUSH
MOTOR BELT.
• Remove the two fixation screws (30:06/108, 45:07/108) from
the two valve holders (30:06/109, 45:07/109) and (30:06/112,
45:07/112).
• Lift out the complete valve unit together with the two valve
holders.
• Disconnect the cables of the valve unit at the connection block.
• Remove the two hoses (30:06/117, 45:07/117) and (30:06/118,
45:07/118) from the fast connectors (30:06/113, 45:07/113)
and (30:06/114, 45:07/114).
• Remove the valve holders from the valve unit.