GTS Technical Manual
14. March 2014 Edition: V1.00/2014 5-34
Copyright © 2014, Diversey Care
05.72.27 mangetic valve & water outlet - valve unit - 30_45_V1.00.fm
5.5 Magnetic valve & water outlet
5.5.7 Removing of valve unit
Picture 48: Valve unit
Remove the two nozzles (30:06/105, 45:07/105) and (30:06/
106, 45:07/106) from the valve unit (30:06/103, 45:07/103).
Remarks
Use the additional tool (30:06/142, 45:07/142) to remove the two
nozzles.
Open fresh water tank according to chapter REMOVING OF FRESH
WATER TANK ASSEMBLY.
Ensure that no water is in the fresh water system before you
disconnect the hoses.
Remove brush cover according to chapter REMOVING OF BRUSH
MOTOR BELT.
Remove the two fixation screws (30:06/108, 45:07/108) from
the two valve holders (30:06/109, 45:07/109) and (30:06/112,
45:07/112).
Lift out the complete valve unit together with the two valve
holders.
Disconnect the cables of the valve unit at the connection block.
Remove the two hoses (30:06/117, 45:07/117) and (30:06/118,
45:07/118) from the fast connectors (30:06/113, 45:07/113)
and (30:06/114, 45:07/114).
Remove the valve holders from the valve unit.
To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com

Table of Contents

Other manuals for Taski procarpet 30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taski procarpet 30 and is the answer not in the manual?

Taski procarpet 30 Specifications

General IconGeneral
BrandTaski
Modelprocarpet 30
CategoryFloor Machine
LanguageEnglish

Related product manuals