8
Setup & Installation
Window Requirements
1. This air conditioner is designed to be installed in a standard single-hung or double-hung
window with a window width between 25” and 36” (645mm - 915mm).
2. The air conditioner can be installed without the side panels to fit in a narrow window opening.
See the windo
w dimensions. If the air conditioner is installed on a window width of 25.39”-
28.35” (645-720mm), it must be installed to the right, and the right bracket must be touching
the air conditioner (not extended); otherwise, the air conditioner will not operate normally.
3. The lower sash (the lower part of the window that moves up and down) must allow for 14.5”
of v
ertical clearance when open.
4. All supporting parts must be secured to firm wood, masonry, or metal.
5. The electrical outlet must be within reach of the power cord. (Electrical outlets only, no power
s
trips or other outlets allowed.)
Suggested Tools for Installation (Not Included)
Note: Store the air conditioner in its product box while not in use.
CAUTION
Hea
vy object. Team handling is required during the installation process.
Phillips
Scr
ewdriver
Scissors
or Knife
Tape Measurer
or Ruler
Pencil Drill and
1/8” Drill Bit
Level
25-36 inch
645-915 mm
14.5 inch
368 mm
Exterior
Wall
OsetStool
Sill
Interior
Wall