ADJUSTMENTS
Before
measuring
and
adjusting
“Overall
frequency
response’,
“Overall
distortion”
and
“Overall
S/N
ratio’,
confirm
that
the
characteris-
tics
of
5
items
below
are
within
standard
which
have
much
relation
to
or
influence
on
electrical
performances
above.
1.
5.
Head
azimuth
adjustment.
2.
Bias
current.
3.
Playback
gain.
4.
Overall
gain.
Playback
frequency
response.
TEST
INSTRUMENTS
1
2.
Prepare
test
instruments
which
are
equivalent
in
accuracy
to
those
shown
below.
The
test
instruments
should
be
inspected
and
corrected
by
specialists
once
every
6
months,
because
a
long
period
of
use
without
maintenance
may
increase
errors
in
indication.
_
Warm-up
the
test
instruments
for
30
minutes
and
the
set
to
be
measured
for
10
minutes
before
taking
the
measurements.
If
not,
there
may
arise
an
error
or
difference
between
the
initial
value
and
the
stabilized
value
measured
after
“aging”.
.
Specifications
of
test
instruments.
(1)
Audio
frequency
oscillator
(2)
a.
Oscillation
frequency
:
5Hz~500
kHz
(5
ranges)
b.
Frequency
tolerance:
+(3%
+1Hz)
c.
Sine
wave
*
Output
voltage:
5Vrms
+
10%
(without
load)
*
Output
frequency
response:
Within
£0.2dB,
20Hz~
20kHz
(at
25°C)
2.5Vrms
+10%
(with
6002
load)
Within
+0.5dB,
5Hz~500
kHz
*
Distortion
factor:
Not
more
than
0.05%,
200
Hz
~
20
kHz
Not
more
than
0.5%,
5Hz~
500
kHz
*
Output
impedance:
6002
unbalanced,
within
+15%
*
Output
attenuator
:
0,
20dB,
Error:
within
+0.2dB
d.
Temperature
in
use
of
set:
|
Temperature=0~
40°C,
Humidity
=
90%
or
less
Automatic-stop
distortion
meter
(with
vacuum
tube
voltmeter)
A.
Distortion
factor
measurement
a.
Frequency
:
400Hz,
1kHz
10%
(fundamental
wave)
b.
Measurement:
0.1~
100%
(6
ranges)
c.
Input:
50mV~50V
d.
Fundamental
wave
attenuation:
60
dB
or
more
B.
Level
measurement
a.
Measurement:
1mV
(—60dB)
~
30
V
(30dB)
(9
ranges)
b.
Frequency
response:
20Hz~100kHz
+0.3dB
(1
kHz
basis)
c.
Input
impedance:
1MQ
+£10%,
less
than
50
pF
d.
Error
in
indicated
value:
Within
+3%
at
1kHz
C.
Output
terminal
a.
Frequency
response:
10Hz~100kHz
+1dB
b
100kHz~1MHz
+3dB
.
Output
voltage:
1Vrms
+10%