Note on H8 and JA10 Blade Roller Pins:
On later meters, a change has been made in blade roller pins.
The exposed end of the pin has been shortened, drilled, and tapped so that it can be extracted by
using a cap screw and a bushing arrangement to jack the pin from the blade rather that having to
drive it out with a drill rod as in the old style. In assembly, pins should be coated with “Anti-Sieze
Lube,” then pressed into position.
2.12. C2 Series Meter
Figure 25 – Removing Collar
Figure 26
Figure 27 – Rotor Removal, Series C2 Meter