Note on H8 and JA10 Blade Roller Pins:
On later meters, a change has been made in blade roller pins.
The exposed end of the pin has been shortened, drilled, and tapped so that it can be extracted by
using a cap screw and a bushing arrangement to jack the pin from the blade rather that having to
drive it out with a drill rod as in the old style. In assembly, pins should be coated with “Anti-Sieze
Lube,” then pressed into position.
2.12. C2 Series Meter




Figure 25 – Removing Collar
Figure 26
Figure 27 – Rotor Removal, Series C2 Meter
Question and Answer IconNeed help?

Do you have a question about the TechnipFMC Smith Meter F4 and is the answer not in the manual?

TechnipFMC Smith Meter F4 Specifications

General IconGeneral
BrandTechnipFMC
ModelSmith Meter F4
CategoryMeasuring Instruments
LanguageEnglish

Summary

Disassembly Procedures for PD Meters

Suggested Tools and Fixtures for Disassembly

Lists essential tools and equipment required to facilitate meter disassembly.

Standard Pressure-Outer Cover Removal

Procedure for removing the outer cover on specific meter models (C2 through JA10-S1 and A1).

High Pressure Packing Gland Maintenance

Guidelines for servicing the high pressure packing gland with glycerine solution.

High Pressure Packing Gland Service

Step-by-step instructions for disassembling and servicing the packing gland assembly.

Gear Train Disassembly

Instructions for removing the gear train components from the meter cover.

Meter Adjustment for Models C2 - G6

Details the procedure for adjusting rotor end clearance on C2 through G6 meter models.

Clearance Checks and Specifications

Reassembly of Smith Meter PD Meters