36
Address
Parameter
Name & Function Default
Unit
Setting
Range
RS232
RS485
Output time setting for Mechanical Brake Signal
Cn003
Brake Signal Timing Sequence:
Implementation a pin for dynamic brake signal(BI) as a output
signal before to perform this function. Refer to sequence
diagram above.
Note: Signal logic level status: 1 = ON. 0 = OFF.
-6-
1 for setting contact the high & Low logic
0 msec
-2000
│
2000
511H
0003H
Motor rotate direction.(Inspect from the load side)
CCW
CW
When Torque or Speed Command value is Positive, the
setting of Motor retation direction are:
Explanation
Setting
Torque Control Speed Control
0 Counter ClockWise(CCW)
Counter
ClockWise (CCW)
1 ClockWise (CW)
Counter
ClockWise (CCW)
2
Counter
ClockWise (CCW)
ClockWise(CW)
Cn004
3 ClockWise (CW) ClockWise (CW)
0 X
0
│
3
512H
0004H